Menu Sub Menu 1 Sub Menu 2 Parameters
Depth Measurement Auto, High Frequency,
Low Frequency
Sonic Correction -7 to +2%
Boat Speed Correction -10 to +10
Water Temp Correction -10 to +10
Speed Correction -10 to +10
Speed Data INT, EXT
Water Temp Data INT, EXT
EXT Trigger Type OFF, ,
(System)
LANGUAGE Japanese, English
GAIN Property Linear, 8800 type
o
STC Property Standard, 8800 type
o
Color Customize 000 - 255
Panel Lock GAIN (H) Knob OFF, ON
GAIN (L) Knob OFF, ON
ENHANCE (H) Knob OFF, ON
ENHANCE (L) Knob OFF, ON
STC AMPTD(H) Knob OFF, ON
STC AMPTD(L) Knob OFF, ON
STC DEPTH(H) Knob OFF, ON
STC DEPTH(L) Knob OFF, ON
RANGE Knob OFF, ON
MODE Knob OFF, ON
VRM Key OFF, ON
IMAGE SPEED Key OFF, ON
IR Key OFF, ON
SHIFT Key OFF, ON
COLOR REJ Key OFF, ON
ALARM Key OFF, ON
EVENT Key OFF, ON
Customize
Panel Brightness 1/5 - 5/5
User Setting 1 - 4
Initialize
Factory Default 1 - 4
Simulator
OFF, ON
6.5 Descriptions of the menu functions
6.5.1 Transmission
6.5.1.1 Pulse Width (H) (L)
Definition and detectable depth of a sounder varies depending on the pulse width. The CVS-841/851
series sounder has 4 selectable pulse widths (Super Short, Short, Middle, Long) for High and Low
frequencies. The characteristic of each pulse width is as follows:
Selections:
Super Short: Image definition is very good but detectable depth is extremely shortened.
Short: Image definition is good but detectable depth is shortened.
Middle: Image definition and detectable depth are improved compared with the Short”.
Long: Detectable depth is lengthened.
Initial setting: Short
0093132682-05 6-5