265
Risk of injury due to unexpected movement of parts!
During the calibration process, there is a risk of injury for persons who stay in the area of lifting
gear, front attachment and discharge chute.
- Make certain no one remains in the swivel range or in the range of movement of lifting
gear, front attachment and discharge chute during the calibration process.
8.6.4.1 Calibration of sensors at lifting unit
The following manual calibration is preferable to automatic calibration of the lifting unit,
see page 302.
Prerequisites
– The lifting unit is adjusted.
– The release switch field mode is switched on.
– The release switch traction drive is switched off.
– The front attachment is mounted.
– The pendulum frame is aligned straight ahead.
– The machine is on a level surface.
– The release switch maintenance is switched off.
– The pick-up/maize header/XDisc operating mode is set according to the mounted front
attachment.
– The front attachment (maize header folded out) is horizontally aligned on level ground.