8.6.12 Menu 3-12 Automatic calibration of sensors at lifting unit
Risk of injury due to unexpected movement of parts!
During the calibration process, there is a risk of injury for persons who stay in the area of lifting
gear, front attachment and discharge chute.
- Make certain no one remains in the swivel range or in the range of movement of lifting
gear, front attachment and discharge chute during the calibration process.
Calibration prerequisites:
Diesel engine speed = idle speed
Release switch "road/field" is set to road mode.
Release switch "traction drive" is switched off.
Release switch "maintenance" is switched off.
Switch "quick-stop console" is not actuated = OFF
Switch "quick-stop manual operation" is not actuated = OFF
The header has been folded out
The seat switch is actuated (the driver's seat is occupied)
The pendulum frame is horizontal.
The machine is on a level surface.
5
6
7
8
B
C
D
BX770219
5
6
7
8
B
C
D
BX770220
Fig. 231
Main menu 3 Maintenance is active.
Using the incremental encoder, choose menu 3-12 Automatic calibration of lifting unit.
Press the incremental encoder.
The display shows menu level Automatic calibration of lifting unit.
Alternatively, the lifting unit can be calibrated manually, see page 264.
To start the calibration, press