Medium Control Unit
34
Pos: 21.14 /BA/Inf o-Center/Schwader/Bedi eneinheit - Mediu m/Swadro 1000/Betriebs bereitschaft @ 2\mod_1 203312466340_78.doc x @ 65196 @ 2 @ 1
6.5 Operational Readiness
• Turn on the medium control unit at the main switch.
Press the
key
A brief self-test follows provided the electrical power supply has been properly connected. All
pilot lights (LED on) of the control panel are briefly lit and a horn sounds a short signal.
Pos: 21.15 /Übersc hriften/Überschri ften 3/P-T/Sensorkontr ollleuchten @ 2\mod_1 203313367371_78.d ocx @ 65235 @ 3 @ 1
6.5.1 Sensor pilot lights
Pos: 21.16 /BA/Inf o-Center/Schwader/Bedi eneinheit - Mediu m/Swadro 1000/Sensorkontr ollleuchten Bi ld SW 1000 @ 2\mod_1203313434 558_78.docx @ 65303 @ @ 1
SW1000029
Figure 12
Pos: 21.17 /BA/Inf o-Center/Schwader/Bedi eneinheit - Mediu m/Swadro 1000/Sensorkontr ollleuchten Te xt @ 2\mod_1203312942543_7 8.docx @ 65254 @ @ 1
The diodes of the corresponding rotors (11) indicate whether the sensors are alive (iron in front
of the sensor).
LED on: Iron in front of the sensor
LED off: No iron in front of the sensor
LED flashing: Sensor has broken cable or short circuit
Pos: 21.18 /BA/Inf o-Center/Schwader/Bedi eneinheit - Mediu m/Swadro 1000/Kreisel f ür eine Funktion vorwählen @ 2\ mod_1203313671715_78. docx @ 65322 @ 23 @ 1
6.6 Settings
6.6.1 Selecting the Rotors for a Function
By using keys
and the rotors are selected for the function which needs to be
performed (depending on the equipment on the machine and the selected function).
LED on: Rotor selected
LED off: Rotor not selected
Pos: 21.19 /BA/--- ------------ Seitenumbruch------ ---------- @ 0\mod_119617 5311226_0.doc x @ 4165 @ @ 1