Medium Control Unit
41
Pos: 21.34 /BA/Inf o-Center/Schwader/Bedi eneinheit - Mediu m/Swadro 1000/Sensor test @ 3\mod_1206001376370_ 78.docx @ 74265 @ 2 @ 1
6.13 Sensor test
SW1000039
Fig. 19
In the sensor test the sensors installed on the machine are checked for faults.
Switch on sensor test.
When the key is held down
, switch on the control unit via the key .
The control unit switches to the sensor test (pilot lamp (11) flashes).
Possible sensors (depending on features of the machine)
No. Sensor designation Status options
14a Sensor Rotor Position 1,2,3
14b Sensor rotor distance 1,2,3
15a Sensor rotor on left in transport position 1,2,3
15b Sensor rotor on right in transport position 1,2,3
Status options
1 LED on: alive (iron in front of the sensor)
2 LED off: deactivated (no iron in front of the sensor)
3 LED flashes: Sensor defective ( e.g.: broken cable or short-circuit)