2 Safety
9 of 82
Amarex
2573.820/02-EN
2 Safety
!
DANGER
All the information contained in this section refers to hazardous situations.
In addition to the present general safety information the action-related safety
information given in the other sections must be observed.
2.1 General
This operating manual contains general installation, operating and maintenance
instructions that must be observed to ensure safe operation of the system and
prevent personal injury and damage to property.
Comply with all the safety instructions given in the individual sections of this
operating manual.
The operating manual must be read and understood by the responsible specialist
personnel/operators prior to installation and commissioning.
The contents of this operating manual must be available to the specialist
personnel at the site at all times.
Information and markings attached directly to the product must always be
complied with and kept in a perfectly legible condition at all times. This applies
to, for example:
Arrow indicating the direction of rotation
Markings for connections
Name plate
The operator is responsible for ensuring compliance with all local regulations not
taken into account.
2.2 Intended use
The pump set must only be operated within the operating limits described in the
other applicable documents.
Only operate pump sets which are in perfect technical condition.
Do not operate partially assembled pump sets.
Only use the pump to handle the fluids described in the data sheet or product
literature of the pump model.
Never operate the system without the fluid to be handled.
Observe the limits for continuous duty specified in the data sheet or product
literature (Q
min
and Q
max
) (to prevent damage such as shaft fracture, bearing
failure, mechanical seal damage, etc).
When untreated waste water is handled, the duty points in continuous operation
lie within 0.7 to 1.2×Q
BEP
to minimise the risk of clogging/hardening.
Avoid duty points for continuous operation at very low speeds and small flow
rates (<0.7×Q
BEP
).
Observe the minimum flow rate and maximum flow rate indicated in the data
sheet or product literature (to prevent overheating, mechanical seal damage,
cavitation damage, bearing damage, etc.).
Do not throttle the flow rate on the suction side of the system (prevention of
cavitation damage).
Consult the manufacturer about any use or mode of operation not described in
the data sheet or product literature.
Only use the respective impeller types in combination with the fluids described
below.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KSB Amarex and is the answer not in the manual?

KSB Amarex Specifications

General IconGeneral
MaterialCast iron, stainless steel
Operating modeContinuous
TypeSubmersible Pump
ApplicationSewage
Explosion protectionAvailable with explosion protection
Frequency50 Hz, 60 Hz
Impeller TypeMulti-vane

Related product manuals