WARNING
Pump set tipping over or rolling off
Risk of personal injury!
▷ Always secure vertically positioned pump sets against tipping over.
▷ Always secure horizontally positioned pump sets against rolling off.
WARNING
Ambient temperature below the specified minimum
Danger of frost!
▷ Never subject the pump set to ambient temperatures which are lower than
those permitted for the drinking water/antifreeze mixture provided (see section
on drinking water/antifreeze mixture / order documentation).
WARNING
Laying cables at temperatures below zero degrees
Damage to the cables!
▷ Observe the minimum permissible temperature at the cable surface of -25 °C for
moving cables.
▷ Observe the minimum permissible temperature at the cable surface of -40 °C for
stationary cables.
CAUTION
Improper storage
Damage to the power cables!
▷ Support the power cables at the cable entries to prevent permanent
deformation. Observe the minimum bending radius
3)
of the cables.
▷ Only remove the protective caps from the power cables at the time of
installation.
Store the submersible borehole pumps as follows:
1.
In its original packaging: horizontally
2. Without packaging: vertically (with the motor below)
3. In a dry environment
4. Protected against direct sunlight and heat
5. Protected against dirt and dust
6. Protected against freezing
7. Protected against vermin
Further information on storing the pump set after use (⇨ Section 7.5 Page 49).
3.4 Return to supplier
WARNING
Ambient temperature below the specified minimum
Danger of frost!
▷ Never subject the pump set to ambient temperatures which are lower than
those permitted for the drinking water/antifreeze mixture provided (see section
on drinking water/antifreeze mixture / order documentation).
1. Clean the pump set properly from the outside.
3)
See cable manufacturer's documentation or DIN VDE 0298-3.
3 Transport/Temporary Storage/Disposal
14 of 64
UPA, UPZ, BSX