3.2.1 Pulling the pump/motor/pump set upright
WARNING
Incorrect positioning
Personal injury and damage to property!
▷ Position the pump set vertically with the motor below.
▷ Use appropriate means to secure the pump set against overturning and tipping
over.
▷ Refer to the weights given in the data sheet.
WARNING
Improper handling when setting the pump set down in a vertical/horizontal
position
Personal injury and damage to property!
▷ Use appropriate means to secure the pump set against overturning, tipping
over and rolling off.
▷ Maintain adequate safety distance during lifting operations (load may swing
when being lifted).
▷ Use additional supports for the transport holder to secure the pump set against
overturning.
WARNING
Improper handling of the power cable when placing the pump set in vertical
position or transporting it
Personal injury and damage to property!
▷ Secure power cables against falling down.
CAUTION
Improper storage
Damage to the power cables!
▷ Support the power cables at the cable entries to prevent permanent
deformation. Observe the minimum bending radius
2)
of the cables.
▷ Only remove the protective caps from the power cables at the time of
installation.
CAUTION
Excessive bending stress on the pump set
Damage to the pump set!
▷ Choose sling points which prevent excessive bending stress on the pump set.
✓ Suitable lifting equipment for the total weight has been selected and is on hand.
1.
Fasten to a suitable lifting accessory, e.g. mounting plate.
2. Attach the lifting equipment, pull the pump/motor/pump set upright, and
secure it against tipping over.
3.3 Storage and preservation
If commissioning is to take place some time after delivery, we recommend that the
following measures be taken:
2)
See cable manufacturer's documentation or DIN VDE 0298-3.
3 Transport/Temporary Storage/Disposal
UPA, UPZ, BSX