EasyManua.ls Logo

Kuka KR C2 edition05 - Description of the Power Unit

Kuka KR C2 edition05
157 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32 / 157 V3.3 11.07.2007 KRC-AD-KRC2ed05-BA en
KR C2 edition05
Relays
Reset
2.7 Description of the power unit
Overview The power unit includes the following components:
Power supply units
Servo drive modules (KSD)
Fuse elements
Fans
Main switch
5 X4 Connection of external mode selector
switches (optional)
6 X7 CAN connection, I/O board
7 X6 Internal/external power supply and ESC cir-
cuit
8 X5 KCP connection
9 X21 KCP power supply and KCP CAN
10 X20 Interface to selector switch in Shared Pen-
dant (optional)
11 X24 CR OUT interface
12 X25 CR IN interface
13 X22 Peripheral interface for inputs and outputs
14 X23 Safe RDC interface (optional)
15 X1 Internal 24 V power supply
22 X10 QE signals
23 X28 Multi-power tap (OUT1) (optional)
24 X27 Multi-power tap (DeviceNet on MFC)
(optional)
25 X29 Multi-power tap (OUT2) (optional)
26 X13 SafetyBUS Gateway interface (optional)
28 X19A 2nd RDC
29 X11 RoboTeam/E7
30 X26 KUKA Guiding Device (KGD) interface
(optional)
31 X12 Peripheral interface, outputs > 500 mA
32 X16 Internal interface
33 X8 Connection of external controllers, E-STOP
button on control cabinet
34 X31 Connection: robot controller, internal fan
Item Designation Description
Item Designation Description
16 K4 Message: Local E-STOP
17 K3 Message: Local E-STOP
18 K8 Message: Auto-Test
19 K7 Message: Auto-Test
20 K1 Message: Drives ON
21 K2 Message: Drives ON
Item Designation Description
27 KY1 ESC Reset button

Table of Contents