Machine Data
56 of 91
Maschinendaten 12.0400 en
2.1.114 $SERVOMODE
Controller functions
Data type int
min
-- --
Unit -- --
a
ue
max
-- --
Assignment -- --
This machine datum is used exclusively for KUKA--internal development purposes.
2.1.115 $ACC_ACT_MA
Limit value of axial command acceleration
Data type int
min
-- --
Unit %
a
ue
max
-- --
Assignment -- --
a_soll_max=$ACC_ACT_MA/100*“Maximum motor speed”/$raise_time
V_soll_max=$VEL_ACT_MA/100* “Maximum motor speed”*“Reduction factor”/100
“Maximum motor speed”=
G $VEL_AXIS_MA with deactivated energy monitoring ($energy_mon=false) and
non--KUKA kinematic systems.
G With active energy monitoring ($energy_mon=true), a value is calculated from the
dynamic model DYN_DAT[249--254].
2.1.11 6 $VEL_ACT_MA
Limit value of axial command velocity
Data type real
min
-- --
Unit %
a
ue
max
-- --
Assignment -- --
V_soll_max=$VEL_ACT_MA/100* “Maximum motor speed”*“Reduction factor”/100
“Maximum motor speed”=
G $VEL_AXIS_MA with deactivated energy monitoring ($energy_mon=false) and
non--KUKA kinematic systems.
G With active energy monitoring ($energy_mon=true), a value is calculated from the
dynamic model DYN_DAT[249--254].