Multi Edit Mode
Controls Page
5-29
When Scale is set to 50%, the controller sends CC values 0-63, 0 at its lowest position, and 
63 at its highest position. With the Add parameter set to 64, the controller sends CC values 
64-127, 64 at its lowest position, and 127 at its highest position. 
When Scale is set to 200%, the controller sends CC values 0-127, 0 at its lowest position, 
and 127 at its middle position through its highest position. With the Add parameter set to 
64, the controller sends CC values 64-127, 64 at its lowest position, and 127 at its middle 
position through its highest position. 
Curve
e Curve parameter lets you apply dierent curves to the controller values, in order to make 
the controller more or less responsive in certain ranges of controller positions, or to distribute 
high and low values over dierent ranges of controller positions. 
e Linear setting distributes CC values 0-127 evenly over the range of the controller, with 
0 at its lowest position, and 127 at its highest position. is is the default setting.
e Compress settings distributes more of CC values 0-127 over the bottom half of the 
controller range, and fewer CC values over the top half of the controller range. 
e Expand setting distributes more CC values 0-127 over the top half of the controller 
range, and fewer CC values over the bottom half of the controller range. 
e Crossfade setting is designed to be used in combination with the Rvrs Crossfade setting, 
in order to smoothly crossfade between two programs on dierent Zones. Assign the Same 
controller to Destination 7 on two Zones, and select one of these curves for the controller on 
each Zone. 
e Bump setting distributes CC values 0-127 to resemble a bell curve, with 0 at its lowest 
and highest positions, and 127 at its middle position
e Reverse settings (Rvrs Linear, Rvrs Expand, Rvrs Compress, and Rvrs Crossfade) 
distribute values in the reverse compared to the regular version of these settings. For 
example,the Rvrs Linear setting distributes CC values 0-127 evenly over the range of the 
controller, with 0 at its highest position, and 127 at its lowest position. .
Entry
e Entry parameter determines the value of a continuous controller when the current Multi 
is loaded. You can set this parameter to None, or 0-127. 
is parameter aects the selected continuous controller for all Zones. e Scale, Add and 
curve parameters are applied to the Entry value individually on each zone, allowing one 
controller to send dierent values to dierent zones, if desired.
If Entry is set to None, then when you load the current Multi, the continuous controller 
value will not change.