XBCP 2
363
XBCP 2 — specify error correction level by
percentage
Format
XBCP 2, percentage;
Parameter
percentage:
value between 0 and 400
Function
PDF417 supports an error correction scheme. The XBCP 2 command specifies the error
correction level as a percentage of the number of code word values for the data to be
encoded. An illegal value defaults to 10.
Note that XBCP 3, as explained on the next page, sets the error correction level by
predetermined values, and the execution of XBCP 3 disables the setting of XBCP 2, even
if XBCP 2 is executed after XBCP 3, until RES (reset) or XBCP 0.
File
To set 50% error correction level:
!R! RES; XBCP 2, 50;
XBAR;This is an error correction level test;ENDB;
EXIT;