2C9
1-4-35
Maintenance
Description
item No.
U332 Setting the size conversion factor
Description
Sets the coefficient of nonstandard sizes in relation to the A4/11" × 8
1
/
2
" size. The coefficient set here is used to
convert the black ratio in relation to the A4/11" × 8
1
/
2
" size and to display the result in user simulation.
Purpose
To set the coefficient for converting the black ratio for nonstandard sizes in relation to the A4/11" × 8
1
/
2
" size for
copying and printing respectively.
Method
Press the start key. The current setting is displayed.
Setting
1. Change the setting using the zoom +/– keys.
Description Setting range Initial setting
Size conversion factor 0.0 to 3.0 1.0
2. Press the start key. The value is set, and the indication for selecting a maintenance item No. appears.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The indication for
selecting a maintenance item No. appears.
U342 Setting the ejection restriction
Description
Sets or cancels the restriction on the number of sheets to be ejected continuously.
When the restriction is set, the number of sheets that can be ejected continuously to the internal eject tray will
be limited to 250.
Purpose
According to user request, sets or cancels restriction on the number of sheets.
Method
Press the start key.
Setting
1. Select “on” or “oFF” using the zoom +/– keys.
Display Description
on The number of sheets restricted.
oFF The number of sheets not restricted.
Initial setting: on
2. Press the start key. The setting is set. The indication for selecting a maintenance item No. appears.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The indication for
selecting a maintenance item No. appears.
U345 Setting the value for maintenance due indication
Description
Sets when to display a message notifying that the time for maintenance is about to be reached, by setting the
number of copies that can be made before the current maintenance cycle ends.
When the difference between the number of copies of the maintenance cycle and that of the maintenance
count reaches the set value, the message is displayed.
This maintenance mode is effective for only Japanese specification.