USER GUIDE
64
HEATING SYSTEM
Analogue control panel
a) Summer operation (water temperature 40 or 60
°C)
b) Winter operation (heating without water temper-
ature monitoring).
c) Winter operation (heating with water temperature
monitoring).
d) Thermostat.
Drain valve
To manually empty the boiler open the drain valve by
turning the switch to position (a). After the emptying,
close the valve by turning the switch to position (b)
and pushing the button (c).
13.2 Alde heating system
The Alde heating system, operating by means of
circulation of hot water, consists of a boiler and a few
radiators positioned in suitable positions inside the
home unit.
The boiler can be powered by gas or 230 V AC and
provides for environment heating and production of
hot water.
All the functions of the system can be programmed by
the Alde control panel (a). To switch on, operate, and
switch off the system, as well as for all the information
concerning maintenance and safety, carefully read
the manual of the manufacturer, which is provided
together with the vehicle documentation.
Drain valve
To manually empty the boiler open the drain valve by
turning the switch to position (b). After the emptying,
close the valve by turning the switch to position (c)
and pushing the button (d).
• Check the integrity of the heating flue pipe at
regular intervals.
• When there is the risk of freezing, check that
the boiler empties automatically.
• During the winter the use of propane gas is
recommended (the butane gas does not gasify
at temperatures lower than 0 °C).
• Read the producer’s handbook carefully.
THINGS TO DO
• Do not tamper with the flue pipe. Have all
maintenance operations performed by the
Laika Customer Service or the dealer.
THINGS TO AVOID
The valve automatically opens when indoor
temperature is near 3 °C.
NOTE
In case of either automatic or manual emptying,
close the drain valve for later use.
NOTE
a
a
b
d
c
a
c
b
b
d
c