Command Description
Data sent from
PC
Data sent from
6300
PA Read the Pitot Actual value in current units None Pitot Actual
value
KA Read the Pitot Rate Actual value in current units None Pitot Rate Actual
value
SA Read the Static Actual value in current units None Static Actual
value
RA Read the Static Rate Actual value in current units None Static Rate
Actual value
PT Read the Pitot Target value in current units None Pitot Target
value
PT=n Set the Pitot Target value to n in current units n 0 if OK; or
Error code
ST Read the Static Target value in current units None Static Target
value
ST=n Set the Static Target value to n in current units n 0 if OK; or
Error code
KT Read the Pitot Rate Target value in current units None Pitot Rate Target
value
KT=n Set the Pitot Rate Target value to n in current
units
n 0 if OK; or
Error code
RT Read the Static Rate Target value in current units None Static Rate
Target value
RT=n Set the Static Rate Target value to n in current
units
n 0 if OK; or
Error code
PU Read the current Pitot units None n, where n is 1 to
15
PU=n Set the Pitot units to n, per the following table
n Pitot unit
1 Knots
2 Mach
3 Km/hr
4 Mph
5 Pt inHg
6 Qc inHg
7 Pt mbar
8 Qc mbar
9 Pt psi
10 Qc psi
11 Pt mmHg
12 Qc mmHg
13 Pt kpa
14 Qc kpa
15 EPR
n 0 if OK; or
Error code
SU Read the current Static units None n, where n is 1 to
7