CS3E-E Series EtherCAT Closed Loop stepper drive User Manual
Default is Home switch, take effect changes need
restart power
Default is positive limit, take effect changes need
restart power
Default is negative limit, take effect changes
need restart power
Default is user defined, take effect changes need
restart power
Note:
(1) After configuring the input and output functions through the master station software or MotionStudio, it needs to save and
restart the power to take effect.
(2) If the function configuration of the two input ports is repeated, the input port with the smaller number is valid, and the other
input port will be set to GPIO automatically. For example: SI3 and SI4 are configured as positive limit, after saving and restarting,
SI3 function as positive limit,SI4 function as GPIO.
There are two object dictionaries that can be used to monitor input ports:
0x2155 is used to monitor whether the input port is connected to a valid signal;
0x60FD is used to monitor whether the input port is configured with a function
0x2155 Corresponding Input Port Table:
Physical State
Read State1 (3)
Note:
(1) 0x2152+01 indicates that the index is 0x2152,and sub-index is 01.
(2) 0x2155.01 indicates that the index is 0x2155,and bit is bit1.
(3) Read State1: when IN1~IN6 inputs are valid, at this time, it has nothing to do with whether the function is configured, bit0~bit5 of
0x2155 will change to value 1. For example, when only IN5 input port is valid, bit 4 of 0x2155 will be value 1, then 0x2155=F (Decimal
16).
0x60FD Corresponding Function Table:
Logic state
Read state2 (1)
When IN1 is set to GPIO
60FD.04=1
When IN2 is set to GPIO
60FD.05=1
When IN3 is set to GPIO
60FD.06=1
When IN4 is set to GPIO 60FD.07=1
When IN5 is set to GPIO 60FD.08=1
When IN6 is set to GPIO
60FD.09=1