Page 4
OPTIONS / ACCESSORIES
Item
Model
No.
Catalog
No.
Unit Model No.
KGB
024
KGB
030
KGB
036
KGB
048
KGB
060
KGB
072
KGB
074
KGB
090
ECONOMIZER

Standard Economizer - Includes Barometric Relief

K1ECON30A-3- 14D90 OX OX OX OX OX OX OX OX
 Factory O O O O O O O X
Standard Economizer Controls (Not for Title 24)
 C1SNSR64FF1 53W64 OX OX OX OX OX OX OX OX
󰀨 C1SNSR64FF1 53W64 X X X X X X X X




K1ECON32A-3 16X75 OX OX OX OX OX OX OX OX

 C1SNSR60FF1 10Z75 OX OX OX OX OX OX OX OX
󰀨 C1SNSR60FF1 10Z75 X X X X X X X X
Economizer Accessories
Horizontal Economizer Conversion Kit T1HECK00AN1 17W45 X X X X X X X X
POWER EXHAUST FAN
Standard Static
NOTE - Field installed
Power Exhaust Fan
requires “Barometric
Relief Dampers for Power
Exhaust Kit” for eld
installation. See below.
 79W87 X X X X X X
 79W88 X X X X X X
 79W89 X X X X X X
1
BAROMETRIC RELIEF
1
 C1DAMP50A-3- 19D42 X X X X X X

Hood
LAGEDH03/15-2 19F01 X X X X X X X X
OUTDOOR AIR

Motorized C1DAMP21A-1 15D17 OX OX OX OX OX OX OX OX
Manual C1DAMP11A-2 15D18 OX OX OX OX OX OX OX OX
HUMIDITROL
®
CONDENSER REHEAT OPTION
Humiditrol  Factory O O O O O  O
 C0SNSR30FF1L 99N41 X X X X X  X
ELECTRICAL
Voltage

 O O O O O
 O O O O O O
 O O O O O O
 O O O O O O
Disconnect See Electrical Data Tables for selection OX OX OX OX OX OX OX OX
GFI Service
Outlets

LTAGFIK10/15
74M70 OX OX OX OX OX OX OX OX
 67E01 X X X X X X X X
 C1GFCI99FF1 10C89 X X X X X X X X
1

2

3

4
074S models only.



X - Field Installed