EasyManua.ls Logo

Lenovo ThinkSystem DM3010H - Restore and Verify the Configuration - DM3010 H; Step 1: Verify and Set the HA State of the Chassis

Lenovo ThinkSystem DM3010H
137 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.
Recable the console to the controller module, and then reconnect the management port.
3.
Repeat the preceding steps for the second controller in the replacement chassis.
4.
Complete the installation of the controller module:
a.
With the cam handle in the open position, firmly push the controller module in until it meets
the midplane and is fully seated, and then close the cam handle to the locked position.
Do not use excessive force when sliding the controller module into the
chassis to avoid damaging the connectors.
b.
If you have not already done so, reinstall the cable management device.
c.
Bind the cables to the cable management device with the hook and loop strap.
d.
Repeat the preceding steps for the second controller module in the replacement chassis.
5.
Connect the power supplies to different power sources, and then turn them on.
6.
Boot each controller to Maintenance mode:
a.
As each controller starts the booting, press
Ctrl-C to interrupt the boot process when you
see the message Press Ctrl-C for Boot Menu.
If you miss the prompt and the controller modules boot to ONTAP, enter
halt, and then at the LOADER prompt enter boot_ontap, press Ctrl-C
when prompted, and then repeat this step.
b.
From the boot menu, select the option for Maintenance mode.
5.10.4. Restore and verify the configuration - DM3010H
Verify the HA state of the chassis bring up the system,and return the failed part
to Lenovo, as described in the RMA instructions shipped with the kit.
Step 1: Verify and set the HA state of the chassis
You must verify the HA state of the chassis, and, if necessary, update the state to match your
system configuration.
1.
In Maintenance mode, from either controller module, display the HA state of the local controller
module and chassis:
ha-config show
The HA state should be the same for all components.
2.
If the displayed system state for the chassis does not match your system configuration:
a.
Set the HA state for the chassis based on the system’s existing configuration:
ha-config
modify chassis ha-state
The value for HA-state can be one of the following: