Both controllers must be in Maintenance mode to run the interconnect test.
3.
At the LOADER prompt, access the special drivers specifically designed for system-level
diagnostics to function properly: boot_diags
During the boot process, you can safely respond y to the prompts until the Maintenance mode
prompt (*>) appears.
4.
Enable the interconnect diagnostics tests from the Maintenance mode prompt: sldiag device
modify-dev interconnect -sel enable
The interconnect tests are disabled by default and must be enabled to run separately.
5.
Run the interconnect diagnostics test from the Maintenance mode prompt: sldiag device run
-devinterconnect
You only need to run the interconnect test from one controller.
6.
Verify that no hardware problems resulted from the replacement of the chassis: sldiag device
status-dev interconnect -long -state failed.
System-level diagnostics returns you to the prompt if there are no test failures, or lists the full
status of failures resulting from testing the component.
7.
Proceed based on the result of the preceding step.
Step 4: Return the failed part to Lenovo
If you are instructed to return the component, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Important information after replacing the chassis
After replacing the chassis, move the system tag from the old chassis to the new
chassis.