▪ 4-ports, 32Gb Fiber Channel, SFP+
c.
If you have a 2+2 card (2 ports with Ethernet connections and 2 ports with Fiber
Channel connections), cable ports e1a and e1b to your FC data network and ports e1c
and e1d to your Ethernet data network.
▪ 2-ports, 10/25Gb Ethernet (SFP28) + 2-ports 32Gb FC (SFP+)
▪ 2-ports, 32Gb Fiber Channel, SFP+
DO NOT plug in the power cords.
4.2.4. Step 4: Cable controllers to drive shelves
Cable your controllers to external storage.
The example uses DM240S. Cabling is similar with other supported drive shelves.
Be sure to check the illustration arrow for the proper cable connector pull-tab orientation.
About this task
You can use the graphic or the step-by step instructions to complete the cabling between the
controllers and to the drive shelves.
Do not use port 0b2 on a DM3010H. This SAS port is not used by ONTAP and is
always disabled.
Steps
1.
Cable the shelf-to-shelf ports.
a.
Port 1 on IOM A to port 3 on the IOM A on the shelf directly below.