Configuration
Code table
8
8.5
8.5−47
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0780
CFG: N 5250 NLIM1−OUT Selection list 1 Configuration of analog input
signal, function block NSET
l Main setpoint
See System
Manual
(extension)
C0781
CFG: N−INV 10251 R/L/Q−R/L Selection list 2 Configuration of digital input
signal, function block NSET
l HIGH: main setpoint (C0780) is
inverted
C0782
CFG: NADD 55 AIN2−OUT Selection list 1 Configuration of analog input
signal, function block NSET
l Additional setpoint
C0783
CFG:
NADD−INV
1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block NSET
l HIGH: additional setpoint
(C0783) is inverted
C0784
CFG: CINH−VAL 5001 MCTRL−NACT Selection list 1 Configuration of analog input
signal, function block NSET
l The signal is accepted by the
main setpoint integrator when
the controller is inhibited
C0785
CFG: SET 5000 MCTRL−nset2 Selection list 1 Configuration of analog input
signal, function block NSET
l When NSET−LOAD = HIGH, the
signal is accepted by the main
setpoint integrator
C0786
CFG: LOAD 5001 MCTRL−QSP−OUT Selection list 2 Configuration of digital input
signal, function block NSET
l HIGH: The signal at NSET−SET is
accepted by the mains setpoint
integrator
l Control of both ramp function
generators in special
situations, e.g. quick stop
C0787
Selection list 2 Configuration of digital input
signals, function block NSET
l Activation of a fixed speed via
binary coding of the digital
input signals
l For coding see description of
function block NSET
l Parameter setting of the fixed
speeds (JOG setpoints) in
C0039
See System
Manual
(extension)
1 CFG: JOG 53 DIGIN3 NSET−JOG*1
2 CFG: JOG 1000 FIXED0 NSET−JOG*2
3 CFG: JOG 1000 FIXED0 NSET−JOG*4
4 CFG: JOG 1000 FIXED0 NSET−JOG*8
C0788
Selection list 2 Configuration of digital input
signals, function block NSET
l Activation of additional
acceleration and deceleration
times for the mains setpoint
via binary coding of the digital
input signals
l For coding see description of
function block NSET
l Parameter setting of the times
in C0101 and 103
1 CFG: TI 1000 FIXED0 NSET−Ti*1
2 CFG: TI 1000 FIXED0 NSET−Ti*2
3 CFG: TI 1000 FIXED0 NSET−Ti*4
4 CFG: TI 1000 FIXED0 NSET−Ti*8