Configuration
Code table
8
8.5
8.5−20
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0234 damp value 20 −100 {1 %} 100 Influence of the oscillation
damping, function block MCTRL
l Minimising a tendency to
oscillation of the drive
l Influences the tendency to
oscillation of the drive
l When C0025 >1 and
C0006 = 1, C0234 is set to 0
8.2−25
8.2−40
C0235 damping 2 1 {1 ms} 600 Filter time of the oscillation
damping, function block MCTRL
l Filter time for the internal
signal for oscillation damping
8.2−25
8.2−40
C0236 damp limit 1.0 0.0 {0.1 Hz} 20.0 Limit value of oscillation
damping, function block MCTRL
l Limit value for the internal
signal of oscillation damping
C0241 Cmp−RFG−I=0 1.00 0.00 {0.01 %} 100.00 Speed threshold in [%] for the
digital output NSET−controller
enable−I=0, function block NSET
l The analog signals
NSET−NOUT (without
arithmetic and limiting
functions) and
NSET−controller enable−I are
compared
l NSET−controller
enable−I=0 = HIGH: the
differential signal between
NSET−NOUT and
NSET−controller enable−I falls
below the value in C0241
l C0241 = 100 %: n
max
See System
Manual
(extension)
C0244 BRK1 M set 0.00 0.00 {0.01 %} 100.00 Holding torque, function block
BRK1
l C0244 = 100 % = C0057
See System
Manual
(extension)
C0250 FCODE 1 Bit 0 0 1 Free control code FCODE250
C0252 Angle offset 0 −245760000 {1 inc.} 245760000 Phase offset for master
frequency processing, function
block DFSET
l Fixed phase offset for digital
frequency configuration
l 1 rev. = 65536 inc
8.2−18
C0253 Angle n−trim à −32767 {1 inc.} 32767 Speed−dependent phase
trimming for the master
frequency processing, function
block DFSET
à depending on C0005, C0025,
C0490
l Change of C0005, C0025 or
C0490 resets C0253 to the
corresponding Lenze setting
l 1 rev. = 65536 inc
l Value in C0253 is reached at
15000 rpm
efesotomasyon.com - Lenze