Configuration
Code table
8
8.5
8.5−28
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0450
CFG: NX 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block BRK1
l Speed threshold, from which
the drive may output the
signal "Close brake"
See System
Manual
(extension)
C0451
CFG: SET 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block BRK1
l HIGH = close brake
l LOW = open brake
C0452
CFG: SIGN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block BRK1
l Direction of torque with
which the drive is to create a
torque against the brake
C0458 −199.99 {0.01 %} 199.99
Function block BRK1
l Display of the signals linked
in C0450 and C0452
See System
Manual
(extension)
1 DIS: NX
2 DIS: SIGN
C0459 DIS: ON Function block BRK1
l Display of the signal linked in
C0451
C0464 Customer I/F
0 original
Customer interface indicates the
status of the selected basic
configuration
l Reassignment of terminals in
a basic configuration does
not change C0005 and sets
C0464 = 1
l Adding or removing function
blocks or changing the signal
flow among the function
blocks in a basic
configuration sets C0005 = 0
and C0464= 1
1 changed