Configuration
Code table
8
8.5
8.5−34
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0536 −32767 {1} 32767
Function block DFSET
l Display of the signals linked
in C0521, C0522 and C0523
8.2−18
1 DIS: VP−DIV
2 DIS: RAT−DIV
3 DIS: A−TRIM
C0537 DIS: N−TRIM −199.99 {0.01 %} 199.99 Function block DFSET
l Display of the signal linked in
C0524
C0538 0 1
Function block DFSET
l Display of the signals linked
in C0525, C0526 and C0527
1 DIS: 0−pulse
2 DIS: RESET
3 DIS: SET
C0539 DIS: IN −6000 {1 rpm} 6000 Function block DFSET
l Display of the signal linked in
C0520
C0540
Function 0
Function selection, function
block DFOUT
l Output signal at X10
8.2−8
0 Analog input Analog input Signal at DFOUT−AN−IN is
output. Zero track can be input
externally.
1 PH diff input Phase difference
input
Signal at DFOUT−DF−IN is output.
Zero track can be input
externally.
2 Not assigned
3 Not assigned
4 X10 = X9 X9 is output on X10
The input signals are buffered
C0030 is without function
5 X10 = X8 X8 is output on X10
C0541
CFG: AN−IN 5001 MCTRL−NACT Selection list 1 Configuration of analog input
signal, function block DFOUT
l Signal in [%] of C0011
C0542
CFG: DF−IN 1000 FIXEDPHI−0 Selection list 4 Configuration of input signal,
function block DFOUT
l Speed signal
C0544
CFG: SYN−RDY 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block DFOUT
l DFOUT−SYN−RDY = HIGH:
Generating a zero pulse
C0545 PH offset 0 0 {1 inc.} 65535 Phase offset, function block
DFOUT
l Displacing the zero pulse
generated via
DFOUT−SYN−RDY by up to
360 °
l 1 rev. = 65535 inc (360 °)
C0546 Min inc/rev 1000 1 {1 inc.} 2147483647 Masking of the touch probe
signal, function block DFSET
l Suppressing interference
pulses at X5/E4 (actual pulse
of touch probe signal)
l The size of the masking
window between two actual
pulses is set
8.2−18