NOTICE
Unstable LAN connecon due to the use of incorrect cable types.
The LAN connecon may be interrupted.
▶
Exclusively use cables of the CAT5-S/FTP type or beer.
▶
The unit is to be connected only to internal Ethernet networks without exing a facility and
being subjected to TNVs.
NOTICE
High input voltage at the device.
Destrucon of the device.
▶
Observe maximum permissible input voltage.
▶
Fuse device at the input against too high input voltage.
NOTICE
Short circuit at the device due to electrostac discharge.
Destrucon of the device.
▶
The personnel must be free of electrostac charge prior to working on the device.
NOTICE
Free spaces on the backplane bus.
Malfuncon on the backplane bus due to free spaces between the modules.
▶
Connect the modules directly in succession.
NOTICE
Short circuit in the device due to incorrect handling.
Destrucon of the device.
▶
Only plug in and remove the controller and modules of the I/O system 1000 when the
supply voltage is switched o.
Safety instrucons
Residual hazards