Parameter
Address Name / seng range / [default seng] Informaon
0x2022:043 Device commands: Restore
•
Seng can only be changed if applicaon status (displayed in
0x5810:001) is not equal to "1: Running".
•
When the device command has been executed successfully, the value
0 is shown.
•
Do not switch o the supply voltage or remove the SD card from the
controller while the data recovery is being executed!
0 O / ready Only status feedback
1 On / start Start data recovery from USB sck.
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Device disabled)
20 20%
40 40%
60 60%
80 80%
100 100%
101 No SD card connected
102 SD card is write protected
103 SD card is full
104 USB sck not mounted
105 Backup le on USB sck wrong, double or in
the wrong path
107 Device no memory space le
Device funcons
Back up and restore data
Restore data
87