Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17 96
13 Parameter reference
13.2 Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13842
C13843
C13846
C13850
Parameter | Name:
C13842 | Supervisor IP Address
Data type: UNSIGNED_8
10733 = 0x29ED
Display of the supervisor IP address
(Instance attribute 10 (Supervisor IP Address) in the Device Level Ring (DLR) Object (71 / 0x47)
( 128))
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C13842/1 Supervisor IP address (most significant byte)
C13842/2 Supervisor IP Address
C13842/3 Supervisor IP Address
C13842/4 Supervisor IP address (least significant byte)
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13843 | Supervisor MAC ID
Data type: OCTET_STRING
Index: 10732 = 0x29EC
Display of the supervisor MAC ID
(Instance attribute 10 (Supervisor MAC Address) in the Device Level Ring (DLR) Object (71 / 0x47)
( 128))
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13846 | Address Conflict Detection
Data type: UNSIGNED_8
Index: 10729 = 0x29E9
Activation of the address conflict detection (ACD)
(Instance attribute 10 (Selectcd) in the TCP/IP Interface Object (245 / 0xF5)
( 132))
Changing this value requires a reset of the device ("power off/on" or "type 0 reset").
Selection list (Lenze setting printed in bold)
0 Deactivated
1Enable
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13850 | All words to scanner
Data type: INTEGER_16
Index: 10725 = 0x29E5
Display of the I/O data words transferred from the communication module (adapter) to the scanner.
In the subcodes, all I/O data words transferred to the scanner are displayed. However, only the configured I/O data
words are valid.
Display range (min. value | unit | max. value)
-32768 32767
Subcodes Info
C13850/1
...
C13850/32
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT