Configuration
Function blocks
Internal motor control with vector control (MCTRL2)
8
8.2
8.2.7
8.2-53
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0095
Mot Io Æ 0.00 {0.01 A} 1000.00 Motor magnetising current
Æ depending on C0086, C0088
and C0091
z Change of C0086, C0088 and
C0091 sets C0095 to the Lenze
setting
z Change of C0095 sets
C0086 = 0
6.6-1
6.11-5
C0105 QSP Tif 5.00 0.00 {0.01 s} 999.90 Quick stop deceleration time
z The deceleration time refers to
a speed variation of C0011 ... 0
8.2-25
8.2-48
C0107 Holding time 0.00 0.00 {0.01 s} 9999.90 Hold time for automatic DC
injection braking (Auto-GSB)
8.2-25
8.2-48
C0132
Controller
enable fly
delay
Æ 0 {1 ms} 9999 Minimum time for controller
inhibit with active flying restart
circuit, delays the start of the
flying restart process after
controller enable
Æ depending on C0082, C0086,
C0087, C0088, C0089, C0090,
C0091, C0092
A change of one of the codes
resets C0132 to the minimum
time of the selected motor
z Thetimeisderivedfromthe
double rotor time constant
8.2-25
8.2-48
C0140
select direct 0
Search direction during flying
restart process
z Positive direction of rotation:
The motor rotates in CW
direction with view on the
motor shaft
z Negative direction of rotation:
The motor rotates in CCW
direction with view on the
motor shaft
8.2-25
8.2-48
0 NSET Only search in the direction of the
applied setpoint
1 inv. Nset Only search against the direction
of the applied setpoint
2 pos. Only search in positive direction of
rotation
3 neg. Only search in negative direction
of rotation
4 Both, Nset Search at first in the direction of
the applied setpoint and then
against the direction
5 Both,inv.Nset Search at first against the
direction and then in the direction
of the applied setpoint
6 Both pos. Search at first in positive then in
negative direction of rotation
7 Both neg. Search at first in negative then in
positive direction of rotation