Configuration
Code table
8
8.3
8.3-45
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0734 Trigger source 1
0 OSC trigger input
Function block OSZ
z Configure digital input C0732
or C0733 with desired trigger
signal
See System
Manual
(extension)
1 OSZ channel 1
2 OSZ channel 2
3 OSZ channel 3
4 OSZ channel 4
C0735 Trigger level 0 -32767 {1} 32767 Function block OSZ
z Trigger level OSZ channel 1 ...
OSZ channel 4
C0736 Trigger edge 0
0 LOW-HIGH edge
Oscilloscope function
1 HIGH-LOW edge
C0737 Trigger Delay 0.0 -100.0 {0.1 %} 999.99 Function block OSZ
z Setting of pretriggering and
posttriggering
C0738 Sampling period 3
3 1ms
Oscilloscope function
z Time base
See System
Manual
(extension)
4 2ms
5 5ms
6 10 ms
7 20 ms
8 50 ms
9 100 ms
10 200 ms
11 500 ms
12 1s
13 2s
14 5s
15 10 s
16 20 s
17 50 s
18 1min
19 2min
20 5min
21 10 min
C0739 Number of
channels
4 1 {1} 4 Function block OSZ
z Switching on/off the channels
1 = channel 1
2=channel1+2
3 = channel 1 ... 3
4 = channel 1 ... 4
See System
Manual
(extension)
C0740 0 Oscilloscope function
z Reading data memory
1 Read start
position
0 0 {1} 65535 z Provides a pointed access to a
storage block
2 Enable/inhibit
data reading
0
0 No data reading
1 Data reading