Configuration
Code table
8
8.3
8.3-41
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0690 Function 1
1 IN1=IN2
Function selection, function block
CMP3
z Compare input signals at
CMP3-IN1 and CMP3-IN2
See System
Manual
(extension)
2 IN1>IN2
3 IN1<IN2
4 |IN1IN2|
5 |IN1IN2|
6 |IN1| < |IN2|
C0691 HYSTERESIS 1.00 0.00 {0.01 %} 100.00 Hysteresis, function block CMP3
z Hysteresis for input signals
which are not stable and hence
the output oscillates
C0692 Window 1.00 0.00 {0.01 %} 100.00 Window, function block CMP3
z Set the range in which the
signal comparison is to be
apply
C0693
Selection list 1 Configuration of analog input
signal, function block CMP3
1 CFG: IN 1000 FIXED0% CMP3-IN1
2 CFG: IN 1000 FIXED0% CMP3-IN2
C0694 -199.99 {0.01 %} 199.99 Function block CMP3
z Display of the signals linked in
C0693
1 DIS: IN CMP3-IN1
2 DIS: IN CMP3-IN2
C0700
CFG: IN 19523 FCODE-472/3 Selection list 1 Configuration of analog input
signal, function block ANEG1
z The value at ANEG1-IN is
multiplied by -1 and output
See System
Manual
(extension)
C0701 DIS: IN -199.99 {0.01 %} 199.99 Function block ANEG1
z Display of the signal linked in
C0700
C0703
CFG: IN 19523 FCODE-472/3 Selection list 1 Configuration of analog input
signal, function block ANEG2
z The value at ANEG2-IN is
multiplied by -1 and output
See System
Manual
(extension)
C0704 DIS: IN -199.99 {0.01 %} 199.99 Function block ANEG2
z Display of the signal linked in
C0703