EasyManua.ls Logo

Lenze i550 Series - Residual Hazards

Lenze i550 Series
212 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Residual hazards
Even if notes given are taken into consideraon and protecve measures are implemented, the occurrence
of residual risks cannot be fully prevented.
The user must take the residual hazards menoned into consideraon in the risk assessment for his/her
machine/system.
If the above is disregarded, this can lead to severe injuries to persons and damage to property!
Product
Observe the warning labels on the product!
Icon Descripon
Electrostac sensive devices:
Before working on the product, the sta must ensure to be free of electrostac charge!
Dangerous electrical voltage
Be
fore working on the product, make sure there is no voltage applied to the power terminals!
Aer mains disconnecon, the power terminals will sll carry the hazardous electrical voltage for the me
given next to the symbol!
High leakage current:
Carr
y out xed installaon and PE connecon in compliance with EN 61800−5−1 or EN 60204−1!
Hot surface:
Use per
sonal protecve equipment or wait unl the device has cooled down!
Motor
protecon
With some sengs of the inverter, the connected motor can be overheated.
E. g. by longer operaon of self-venlated motors at low speed.
E. g. by longer operaon of the DC-injecon brake.
Protecon of the machine/system
Drives can reach dangerous overspeeds.
E. g. by seng high output frequencies in connecon with motors and machines not suitable for this
purpose.
The inverters do not provide protecon against such operang condions. For this purpose, use
addional components.
Switch contactors in the motor cable only if the controller is inhibited.
Switching while the inverter is enabled is only permissible if no monitoring funcons are acvated.
Motor
If there is a short circuit of two power transistors, a residual movement of up to 180°/number of pole pairs
can occur at the motor! (e. g. 4-pole motor: residual movement max. 180°/2 = 90°).
Degree of protecon - protecon of persons and device protecon
Informaon applies to the mounted and ready-for-use state.
Informaon does not apply to the wire range of the terminals.
-
Terminals that are not wired have low protecon against physical contact.
-
Terminals for large cable cross-secons have lower classes of protecon, e. g. from 15 kW IP10 only.
Safety instrucons
Residual hazards
114

Table of Contents

Other manuals for Lenze i550 Series

Related product manuals