3-phase mains connecon 230/240 V "Light Duty"
Rated data
The output currents apply to these operang condions:
•
A
t a switching frequency of 2 kHz or 4 kHz: Ambient temperature above 40 °C with a rated output current
reduced by 2.5 %/°C.
•
If the load characterisc "Light Duty" and the switching frequencies 8 kHz or 16 kHz are selected, only the
v
alues of the load characterisc "Heavy Duty" are reached.
Inverter I55AE240C I55AE255C
Rated power kW 5.5 7.5
Rated power hp 7.5 10
Mains voltage range 3/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-230/240 V
Rated mains current
Without mains choke A 25.8 -
With mains choke A 18.9 24.2
Apparent output power kVA 8 10.5
Rated output current
2 kHz A 20.6 27.6
4 kHz A 20.6 27.6
8 kHz A - -
16 kHz A - -
Power loss
2 kHz W 124 190
4 kHz W 131 200
8 kHz W - -
16 kHz W - -
For controller inhibit W 6 6
Cyclic mains switching 3 mes per minute
Max. motor cable length
shielded
Without EMC category m 50 50
Category C1 (2 kHz, 4 kHz, 8
kHz)
m - -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m - -
Category C3 (2 kHz, 4 kHz, 8
kHz)
m - -
Weight kg 2.1 2.1
Weight lb 4.6 4.6
Technical data
3-phase mains connecon 230/240 V "Light Duty"
Ra
ted data
196