EtherCAT
Typical topologies
Line
IN OUT
M
R
SDn
SD2
SD1
IN OUT IN
M Master
SD Slave Device
Bus-related
informaon
Name EtherCAT
Communicaon medium Ethernet 100 Mbps, full duplex
Use Connecon of the inverter to an
EtherCAT network
Connecon system RJ45
Status display 2 LEDs
Connecon designaon IN: X246
OUT: X247
LED "RUN"
Blinking paern State Meaning
o
OFF No supply voltage.
Inialisaon (Init) Network not acve
No data transfer
Blinking 1:1
Pre-Operaonal (Pre-Op) Access possible
No pr
ocess data transfer
Blinking slowly 3:1
Safe-Operaonal (Safe-Op) States of the safe inputs are readable.
on
Operaonal (Op) Data transfer in acon
Basic network sengs
The rotary encoder switch allows you to set an EtherCAT idener.
x16 x1
Seng Idener
0x00 Value from parameter
0x01 ... 0xFF Switch posion
Electrical installaon
Networks
E
therCAT
173