Single−axis controllers
Wiring
Devices in the range 32 ... 104 A (15 ... 55 kW)
3
122
EDS94SPP101 EN 10.2
3.7.5 Devices in the range 32 ... 104 A (15 ... 55 kW)
Example circuit
L3
N
PE
L1
L2
F1...F3
F4
K1
K1
K1
L1 L2
L3
E94ASxExxxx
X100
-UG
O
I
+UG
R
B
R
B
U
Rb1 Rb2
VW
X105
BD1
BD2
X107
X7
T1
T2
X106
M
3~
R
Y
J
J
EYF...
7 2
+
-
+
-
?
+
+
X2
24ESB GE
X3
A1-A1+
RFR
X5
GI
RFR
+
-
"
+
Z1
"
+
-
+
-
?
SSP94PSP67
Fig. 3−24 Basic circuit diagram of the drive system
E94ASxExxxx Servo axis module 9400 Single
F1 ... F4 Fuses
Z1 Toroidal core, effective in the high−frequency range 30 ... 60 MHz
HF−shield termination through large−surface connection to functional earth
EYF... System cable − resolver feedback
RFR Controller enable
K1 Mains contactor
R Resolver
RB Brake resistor
Y Motor holding brake (an optimum motor brake control)
Speed setpoint selection via analog input 1 (−10 ... 0 ... +10 V)
Voltage source for the motor holding brake
24−V voltage source for digital inputs according to IEC 61131−2
24−V voltage source for the control electronics