Single−axis controllers
Rated data
Operation at rated mains voltage 400 V
3
49
EDS94SPP101 EN 10.2
3.4.3 Operation at rated mains voltage 400 V
Device size 1 ... 6
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 400 320 − 0 % ... 440 + 0 % 45 − 0 % ... 65 + 0 %
2/PE DC 565 455 − 0 % ... 620 + 0 % −
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94ASxE0024 1.5 2.1 0.9 0.37 0.5
E94ASxE0034 2.5 3.5 1.6 0.75 1
E94ASxE0044 3.9 5.5 2.5 1.5 2
E94ASxE0074 7.0 9.9 4.4 3 4
E94ASxE0134 12.0 16.8 8.1 5.5 7.5
E94ASxE0174 15.0 21.0 10.3 7.5 11
E94ASxE0244 20.5 29.0 14.7 11 15
E94ASxE0324 − 29.0 20.0 15 20
E94ASxE0474 − 43.0 29.3 22 29
E94ASxE0594 − 54.0 36.8 30 40
Device size 7
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 400 320 − 0 % ... 440 + 0 % 45 − 0 % ... 65 + 0 %
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94ASxE0864 − 79.0 53.6 45 60
E94ASxE1044 − 95.0 64.8 55 73