Single−axis controllers
Rated data
Operation at rated mains voltage 400 V
3
50
EDS94SPP101 EN 10.2
Device size 81 ... 91
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 400 340 − 0 % ... 440 + 0 % 48 − 0 % ... 65 + 0 %
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94BSxE1454 138 90 75 100
E94BSxE1724 164 107 90 125
E94BSxE2024 192 126 105 140
E94BSxE2454 236 153 130 170
E94BSxE2924 285 182 150 205
E94BSxE3664 349 228 190 255
E94BSxE4604 436 287 240 320