Single−axis controllers
Rated data
Operation at rated mains voltage 400 V
3
50
EDS94SPP101 EN 10.2
Device size 81 ... 91
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 400 340 − 0 % ... 440 + 0 % 48 − 0 % ... 65 + 0 %
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94BSxE1454 − 138 90 75 100
E94BSxE1724 − 164 107 90 125
E94BSxE2024 − 192 126 105 140
E94BSxE2454 − 236 153 130 170
E94BSxE2924 − 285 182 150 205
E94BSxE3664 − 349 228 190 255
E94BSxE4604 − 436 287 240 320