EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety instructions
Residual hazards
2
30
EDS94SPP101 EN 10.2
2.3 Residual hazards
Protection of persons
ƒ Before working on the controller, check if no voltage is applied to the power
terminals because
because the power terminals U, V, W, +UG, −UG, Rb1 and Rb2 carry hazardous
voltages for up to 30 minutes after power−off depending on the device.
the power terminals L1, L2, L3; U, V, W, +UG, −UG, Rb1 and Rb2 carry hazardous
voltages when the motor is stopped.
Device protection
ƒ Plug on or pull off all pluggable terminals only in deenergised condition!
ƒ Detach the controllers only in deenergised conditions from their installation
backplanes or the back panel of the control cabinet!
ƒ Cyclic switching on and off of the mains voltage can overload and destroy the input
current limitation of the controller:
Cyclic mains switching of 5−times in 5 minutes is permissible without restrictions.
Motor protection
ƒ Depending on the controller settings, the connected motor can be overheated by:
For instance, longer DC−braking operations.
Longer operation of self−ventilated motors at low speed.
Protection of the machine/system
ƒ Drives can reach dangerous overspeeds (e.g. setting of high output frequencies in
connection with motors and machines unsuitable for such conditions):
The controllers do not offer any protection against such operating conditions. Use
additional components for this purpose.

Table of Contents

Other manuals for Lenze L-force 9400

Related product manuals