Single−axis controllers
Rated data
Operation with rated mains voltage 480 V
3
55
EDS94SPP101 EN 10.2
3.4.4 Operation with rated mains voltage 480 V
Device size 1 ... 6
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 480 340 − 0 % ... 528 + 0 % 45 − 0 % ... 65 + 0 %
2/PE DC 675 480 − 0 % ... 746 + 0 % −
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94ASxE0024 1.3 1.8 1.0 0.37 0.5
E94ASxE0034 2.2 3.1 1.6 0.75 1
E94ASxE0044 3.4 4.8 2.6 1.5 2
E94ASxE0074 6.1 8.6 4.6 3 4
E94ASxE0134 10.5 14.7 8.5 5.5 7.5
E94ASxE0174 13.1 18.4 10.8 7.5 10
E94ASxE0244 17.9 25.4 15.4 11 15
E94ASxE0324 − 26.0 21.0 15 20
E94ASxE0474 − 39.0 31.4 22 29
E94ASxE0594 − 47.0 38.9 30 40
Device size 7
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 480 340 − 0 % ... 528 + 0 % 45 − 0 % ... 65 + 0 %
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94ASxE0864 − 70.0 58.0 45 60
E94ASxE1044 − 84.0 70.0 55 73