Single−axis controllers
Rated data
Operation with rated mains voltage 480 V
3
55
EDS94SPP101 EN 10.2
3.4.4 Operation with rated mains voltage 480 V
Device size 1 ... 6
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 480 340 − 0 % ... 528 + 0 % 45 − 0 % ... 65 + 0 %
2/PE DC 675 480 − 0 % ... 746 + 0 %
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94ASxE0024 1.3 1.8 1.0 0.37 0.5
E94ASxE0034 2.2 3.1 1.6 0.75 1
E94ASxE0044 3.4 4.8 2.6 1.5 2
E94ASxE0074 6.1 8.6 4.6 3 4
E94ASxE0134 10.5 14.7 8.5 5.5 7.5
E94ASxE0174 13.1 18.4 10.8 7.5 10
E94ASxE0244 17.9 25.4 15.4 11 15
E94ASxE0324 26.0 21.0 15 20
E94ASxE0474 39.0 31.4 22 29
E94ASxE0594 47.0 38.9 30 40
Device size 7
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 480 340 − 0 % ... 528 + 0 % 45 − 0 % ... 65 + 0 %
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94ASxE0864 70.0 58.0 45 60
E94ASxE1044 84.0 70.0 55 73

Table of Contents