Multi−axis controllers
Mechanical installation
Devices in the range 2 ... 32 A (0.37 ... 15 kW)
4
193
EDS94SPP101 EN 10.2
4.6.2 Devices in the range 2 ... 32 A (0.37 ... 15 kW)
Mounting grid
We recommend to provide the mounting plate with a grid pattern of M5 threaded holes
for attaching the devices. This preparation enables easy attachment of the devices, and the
device sizes 1, 2, ... n can thus be mounted directly adjacent to each other.
Note!
ƒ M5 screw and washer assemblies or hexagon socket screws with washers
are permitted.
ƒ Tightening torque: 3.4 Nm / 30 lb−in.
ƒ In the installation backplane, the screwed connection may not jut out more
than 7 mm.
SSP94PN010
Fig. 4−8 Mounting grid for device size 1 ... 3 installation backplanes
Installation backplane
Grid hole pattern for installation backplane (M5 threaded holes)
Grid hole pattern for footprint filter (not relevant here)
Cable duct
1 ... 3 Device size, mounting holes used