Single−axis controllers
Rated data
Operation at rated mains voltage 230 V
3
46
EDS94SPP101 EN 10.2
3.4.2 Operation at rated mains voltage 230 V
Device size 1 ... 6
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 230 180 − 0 % ... 264 + 0 % 45 − 0 % ... 65 + 0 %
2/PE DC 325 260 − 0 % ... 370 + 0 % −
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94ASxE0024 1.5 2.1 0.5 0.18 0.25
E94ASxE0034 2.5 3.5 0.9 0.37 0.5
E94ASxE0044 3.9 5.5 1.4 0.75 1
E94ASxE0074 7.0 9.9 2.5 1.5 2
E94ASxE0134 12.0 16.8 4.7 3 4
E94ASxE0174 15.0 21.0 5.9 4 5.5
E94ASxE0244 20.5 29.0 8.4 5.5 7.5
E94ASxE0324 − 29.0 11.5 7.5 10
E94ASxE0474 − 43.0 16.9 11 15
E94ASxE0594 − 54.0 21.2 15 20
Device size 7
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 230 180 − 0 % ... 264 + 0 % 45 − 0 % ... 65 + 0 %
Mains current at I
aN
Output power Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LN
[A] I
LN
[A] S
aN
[kVA] P
aN
[kW] P
aN
[hp]
E94ASxE0864 − 79.0 30.8 22 29
E94ASxE1044 − 95.0 37.3 30 40