DC−bus operation
Rated data
General data
7
341
EDS94SPP101 EN 10.2
7.4 Rated data
7.4.1 General data
The total current of the nominal input currents I
DC
to be provided by the power supply
module or one or several single−axis controllers must be determined. The DC cables must
be dimensioned in accordance with the total current.
The number of devices in a drive system can be limited by the DC−bus capacity and the
charging current (I
charging,
permissible
> (I
charging
at
U
r
)).
Additional data
Type
Input current DC−bus
capacity
Charging
resistor
I
charging
at V
Lr
permissible
I
DC
at I
ar
[A]
[F] [] 400 V
[A]
480 V
[A]
[A]
Power supply modules
E94APNE0104 − − − − − 90
E94APNE0364 − − − − − 154
E94APNE1004 − − − − − 278
E94APNE2454 − − − − − 520
Regenerative power supply modules
E94ARNE0134 20.6 495 100 5.7 7.1 154
E94ARNE0244 35.5 990 50 11.3 14.1 154
Multi Drives
E94AMxE0024 2.6 165 100 5.7 7.1 −
E94AMxE0034 4.3 165 100 5.7 7.1 −
E94AMxE0044 6.7 330 100 5.7 7.1 −
E94AMxE0074 12.1 330 100 5.7 7.1 −
E94AMxE0094 15.4 495 50 11.3 14.1 −
E94AMxE0134 20.6 495 100 5.7 7.1 −
E94AMxE0174 25.7 825 50 11.3 14.1 −
E94AMxE0244 35.5 990 50 11.3 14.1 −
E94AMxE0324 48.0 1320 50 11.3 14.1 −
E94AMxE0474 52.6 2200 27 21.0 25.1 154
E94AMxE0594 66.1 2200 27 21.0 25.1 154