DC−bus operation
Rated data
General data
7
342
EDS94SPP101 EN 10.2
Additional data
I
charging
Charging
resistor
DC−bus
capacity
Input current
Type
permissibleat V
Lr
Charging
resistor
DC−bus
capacity
Input current
Type
[A]
480 V
[A]
400 V
[A]
[][F]I
DC
at I
ar
[A]
Type
Single Drives
E94ASxE0024 2.6 165 100 5.7 6.8 20.4
E94ASxE0034 4.3 165 100 5.7 6.8 20.4
E94ASxE0044 6.7 330 100 5.7 6.8 49.0
E94ASxE0074 12.1 330 100 5.7 6.8 49.0
E94ASxE0134 20.6 495 100 5.7 6.8 154
E94ASxE0174 25.7 825 50 11.3 13,6 154
E94ASxE0244 35.5 990 50 11.3 13,6 154
E94ASxE0324 35.5 2200 27 21.0 25.1 154
E94ASxE0474 52.6 2200 27 21.0 25.1 154
E94ASxE0594 66.1 2200 27 21.0 25.1 154
Tab. 7−1
DCbus = DC bus
I
charging
= charging current
The devices listed below are not permissible as direct DC−connection nodes on the DC link
level. Get in touch with your Lenze contact person to find out whether solutions and
measures have been worked out for your particular application.
Additional data
Type
Input current DC−bus
capacity
Charging
resistor
I
charging
at V
Lr
permissible
I
DC
at I
ar
[A]
[F] [] 400 V
[A]
480 V
[A]
[A]
E94ASxE0864 96.8 3300 68 8.3 10.0 358
E94ASxE1044 116 3300 68 8.3 10.0 358
E94BSxE1454 171 6000
1)
5.0 5.0 356
E94BSxE1724 203 8000
1)
6.7 6.7 423
E94BSxE2024 239 8000
1)
6.7 6.7 496
E94BSxE2454 290 8000
1)
6.7 6.7 603
E94BSxE2924 343 8000
1)
6.7 6.7 713
E94BSxE3664 434 16000
1)
13.4 13.4 901
E94BSxE4604 544 16000
1)
13.4 13.4 1130
Tab. 7−2
DCbus = DC bus
I
charging
= charging current
1)
Charge with constant current