EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power supply modules
Rated data
Operation at rated mains voltage 230 V
5
243
EDS94SPP101 EN 10.2
5.3.2 Operation at rated mains voltage 230 V
Input data
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 230 180 − 0 % ... 264 + 0 % 45 − 0 % ... 65 + 0 %
Voltage Continuous input power
Type [V] S
L
[kVA]
E94APNE0104 230 3.2
E94APNE0364 230 11.5
E94APNE1004 230 32.6
E94APNE2454 230 79.6
Output data
Mains Volta
g
e Volta
g
e ran
g
e Fre
q
uenc
y
ran
g
e
Voltage
U
DC
[V]
Voltage
range
U
DC
[V]
Frequency
range
f [Hz]
2/PE DC 325 260 − 0 % ... 370 + 0 %
Output current and output power
100 % 5−s cycle 3−min cycle
Type I
DC
[A] P
DC
[kW] I
DC
[A] P
DC
[kW] I
DC
[A] P
DC
[kW]
E94APNE0104 10 2.1 40 8.4 15 3.2
E94APNE0104
+ E94AZMP0084
10 2.8 40 11.2 15 4.2
E94APNE0364 36 7.5 108 22.5 54 11.3
E94APNE0364
+ E94AZMP0294
36 10.1 108 30.3 54 15.5
E94APNE1004 100 20.8 200 41.6 150 31.2
E94APNE1004
+ E94AZMP0824
100 27.9 200 55.8 150 41.9
E94APNE2454 245 51 368 76.5 368 76.5
E94APNE2454
+ E94AZMP2004
245 68.5 368 103 368 103
100 % Permanent rated values
5−s cycle Cycle for the second−range
(0.5 s overload/4.5 s recovery time with 75 % of the permanent rated value)
3−min cycle Cycle for the minute−range
(60 s overload/120 s recovery time with 75 % of the permanent rated value)

Table of Contents