Power supply modules
General data and operating conditions
5
241
EDS94SPP101 EN 10.2
Operating conditions
Environmental conditions
Climate
Storage
IEC/EN 60721−3−1 1K3 (−25 ... +60 °C)
Transport IEC/EN 60721−3−2 2K3 (−25 ... +70 °C)
Operation IEC/EN 60721−3−3 3K3 (−10 ... +55 °C)
Current derating from +45 ... +55 °C: 2.5 %/°C
Site altitude 0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m
Pollution EN 61800−5−1 Degree of pollution 2
Vibration resistance (9.81 m/s
2
= 1 g)
Transport
IEC/EN 60721−3−2 2M2
EN 61800−2
2 ... 9 Hz: Amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
2
200 ... 500 Hz: acceleration resistant up to 15 m/s
2
Operation
Germanischer Lloyd 5 ... 13.2 Hz: Amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
IEC/EN 60068−2−6
10 ... 57 Hz: Amplitude 0.075 mm
57 ... 150 Hz: Acceleration resistant up to 1 g
Assignment of filters to standard devices
DC power supply module Mains filter
(corresponds to "long
distance")
RFI filter
(corresponds to "short
distance")
Mains choke
E94APNE0104 E94AZMP0084 E94AZRP0084 EZAELN3008B372
E94APNE0364 E94AZMP0294 E94AZRP0294 EZAELN3030B961
E94APNE1004 E94AZMP0824 E94AZRP0824 EZAELN3080B371
E94APNE2454 E94AZMP2004 E94AZRP2004 EZAELN3200B151
With RFI filters, EMC categories can be achieved.
With mains filters, EMC categories and a power increase P
DC
can be achieved.
With mains chokes, a power increase P
DC
is achieved (through reduction of the harmonic
content). For adherence to EMC categories, additional further measures are necessary.
General electrical data
Power loss P
V
[W]
Type Total (when operating with I
aN
) Constant (control electronics only)
E94APNE0104 55 5
E94APNE0364 110 5
E94APNE1004 230 7
E94APNE2454 550 7