EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power supply modules
Mechanical installation
Devices in the range 100 ... 245 A (48 ... 119 kW)
5
265
EDS94SPP101 EN 10.2
Arrangement of the devices
L1
L2
L3
M
3~
M
3~
M
3~
M
3~
E94AZxPxxxx
E94AZxPxxxx
E94AZxPxxxx
E94APNExxxx
E94AZEX100
E94AZPxxxxx
E94AZPxxxxx
E94AZPxxxxx
E94AZPxxxxx
...
...
+UG
-UG
+UG
-UG
+UG
-UG
01
+
(E94AZPPxxxx)
SSP94FF003
Fig. 5−4 Arrangement concept
Standard mounting: side mounting
Mounting variant: top mounting
E94AZxPxxxx Filter
E94APNExxxx 9400 DC power supply module
(up to 36 A/18 kW with E94AZPPxxxx installation backplane)
E94AZEX100 DC input module
E94AZPxxxxx Installation backplane for 9400 axis module
A DC−bus connection has to be planned and dimensioned taking the technical data into
account.
How to arrange the devices via the DC busbars for operation in the DC−bus connection:
ƒ Arrange the devices in a row from left to right.
ƒ Install the supplying device on the left:
DC power supply module (in a first row),
DC input module (in the following rows).
ƒ Install the multi drive axis controllers to the right from the highest to the lowest
power (recommendation).
ƒ For increasing the braking power also single drive axis controllers can be integrated.
For this purpose these axis controllers have to be equipped with the optional busbar
mounting set (E94AZJAxxx).