Power supply modules
Wiring
Devices in the range 10 ... 36 A (4 ... 18 kW)
5
274
EDS94SPP101 EN 10.2
Tip!
Complete the wiring of the installation backplane before plugging in the
standard device. The upper terminals of the installation backplane cannot be
connected with a plugged−in standard device.
Mains
Terminal X111
(left part)
Labelling Description
L1
L2
L3
Connection of the mains phases L1, L2, L3
Connection for the supply−side PE conductor with M5 ring cable lug
SSP940X111
Terminal X112
(right part)
Labelling Description
L1
L2
L3
Alternative connection at the bottom: mains phases L1, L2, L3
Connection for the supply−side PE conductor with M5 ring cable lug
SSP940X112
Terminal data
Max. conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
Device sizes 1 + 2:
flexible
with wire end ferrule
2.5
12 0.5 ... 0.6 4.5 ... 5.3 PZ0
Device size 3:
flexible
with/without wire end
ferrule