EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Regenerative power supply modules
Rated data
Mains filters for regenerative power supply modules
6
303
EDS94SPP101 EN 10.2
With different motor cable lengths, per axis at least 25 % of the longest cable must be
considered when calculating the total motor cable length.
Example: 1 Motor cable length l
mot
[m]
Axis Actual
value
min. 25 % of the longest cable To be considered
16
0.25 * 20 = 5
6
2 ... 4 3 * 10 3 * 10
5 20 20
Total 56 max. permissible for 5 axes: < 60 56
EMC class C2 will be complied with.
Example 2 Motor cable length l
mot
[m]
Axis Actual
value
min. 25 % of the longest cable To be considered
1 ... 4 4 * 5 0.25 * 40 = 10 4 * 10
5 40 40
Total 60 max. permissible for 5 axes: < 60 80
EMC class C2 will not be complied with.
Example: 3 Motor cable length l
mot
[m]
Axis Actual
value
min. 25 % of the longest cable To be considered
1 ... 3 3 * 100
0.25 * 100 = 25
3 * 100
4 50 50
5 ... 10 6 * 15 6 * 25
Total 410 max. permissible for 10 axes: < 500 500
EMC class C2 will be complied with.
Example: 4 Motor cable length l
mot
[m]
Axis Actual
value
min. 25 % of the longest cable To be considered
1 ... 4 4 * 100
0.25 * 100 = 25
4 * 100
5 ... 10 6 * 15 6 * 25
Total 490 max. permissible for 10 axes: < 500 550
EMC class C2 will not be complied with.