Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHB0101
8
474
EDS94SPP101 EN 10.2
General electrical data
EMC
Noise emission EN 61800−3
Conducted, category C2.
Noise immunity EN 61800−3
Burst on control cable: 2 kV/5 kHz
Surge on control cable: 1 kV (1.2 s/50 s; control
cable − PE)
Rated data
Voltage Frequency Rated current [A]
Number of
phases
[V] [Hz] up to +45 °C up to +55 °C
E94AZHB0101 24 0 (DC) 0.3 ... 5 0.3 ... 5 2
Temperature in the control cabinet
Area Values
Input voltage DC 24 V (18 ... 30 V)
Output voltage Corresponds to input voltage
Brake current 0.3 ... 5 A
Switching capacity Max. 110 W
Breaking energy Max. 10 Ws
Cable protection Recommendation: 7.5 A, tripping characteristic "B" or "C"
Maximum cable length In the chapter "Electrical installation" the dependency of the cable length on
the brake current and the cable cross−section is described.
Operating frequency Max. 6/min
Operating times Can be ignored compared to the delay time of the brake.
See documentation of the brake.
Service life > 10 millions of cycles
Protection against
Overload No
Short circuit of the
terminals
Yes
Polarity reversal at the
input
Yes
Insulation
1)
Double insulation (EN61800−5−1: V
rated
= 300 V AC),
Separation (UL: V
rated
= 500 V AC)
1)
Brake connection against control card of the controller