Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHN0025
8
486
EDS94SPP101 EN 10.2
Rated data
Voltage Frequency Rated current [A]
Number of
phases
[V] [Hz] up to +45 °C up to +55 °C
E94AZHN0025 230/290 50/60 0.75/0.75 0.54/0.54 1
E94AZHN0025 205/260 0 (DC) 0.75/0.75 0.54/0.54 1
Temperature in the control cabinet
Area Values
Input voltage AC 230 V (180 ... 317 V), 45 ... 65 Hz
Output voltage DC 205 V With mains voltage of AC 230 V
Brake current 0.1 ... 0.75 A
Cable protection Recommendation: 5 A, tripping characteristic "B" or "C"
Control input DI
Signalling output DO
Control voltage
DC 24 V, PLC level
HIGH
LOW
DC +15 ... 30 V
DC 0 ... +3 V
Control current
Input 5 ... 10 mA
Output 5 ... 50 mA
Protective function Protected against polarity reversal up to DC 60 V
Max. connectable cable
cross−section
2.5 mm
2
AWG 12
Maximum cable length 150 m
Permissible operating frequencies
Recommended brake Power Coil: Voltage DC 205 V Permissible operating frequency
Type P [W] L [H] I [A] (20 °C) [1/min]
BFK457−06E
BFK458−06E
20
76 0.10 60
BFK457−08E
BFK458−08E
25 66 0.12 60
BFK457−10E
BFK458−10E
30 85 0.15 60
BFK457−12E
BFK458−12E
40 107 0.20 40
BFK457−14E
BFK458−14E
50 102 0.24 30
BFK457−16E
BFK458−16E
55 127 0.27 20
BFK457−18E
BFK458−18E
85 100 0.41 10
BFK457−20E
BFK458−20E
100 115 0.49 8
BFK457−25E
BFK458−25E
110 134 0.54 6