Accessories (overview)
Filters
Sinusoidal filters EZS3−xxxA200 4 ... 90 A
8
599
EDS94SPP101 EN 10.2
Identification
Type:
SINUSFILTER
SINE-FILTER
FILTRE-SINUS
L
SSP94SF002
Type code e Z S 3 xxxA xxx
Product series
Accessories
Filter type
S = sinusoidal filter
Phases
3 = 3 phases
Rated current [A] (rounded)
Variant
Operating conditions
A sinusoidal filter (LC filter) in the motor cable limits the rate of rise of voltage (du/dt
< 500 V/s) and the capacitive charge/discharge currents which occur during inverter
operation. This enables considerably larger shielded motor cables and the service life of the
motor is increased.
The following must be observed when using sinusoidal filters:
ƒ Use sinusoidal filters only together with standard asynchronous machines 0 ...
550 V.
ƒ The operation is only permissible using a V/f or V/f
2
characteristic control.
ƒ The operation is only permissible using a switching frequency of 4 ... 8 kHz.
The sinusoidal filter overheats when being operated with a switching frequency
< 4 kHz.
Ensure that the automatic switching frequency reduction is deactivated (see
documentation of the basic device).
ƒ Limit the output frequency to maximally 150 Hz.
ƒ Please note, when dimensioning the controller, that the controller has an additional
load of 10 ... 15 %.